AD Amdt-39-9773

Recurring final rule
Data completeness: 70%

Airworthiness Directives; JanAero Devices B-Series Combustion Heaters, Models B1500, B2030, B3040, and B4050 (formerly owned by Janitrol, C&D, FL Aerospace, and Midland-Ross Corporation)

AD Number
Amdt-39-9773
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 95-CE-83-AD
FR Citation
61 FR 51357

Unsafe Condition

Failure of the heater combustion tube assembly or combustion air pressure switch can cause an airplane fire or explosion, as evidenced by two occurrences including an explosion that blew off the baggage compartment door and a fire in flight.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Repetitively test the combustion tube via pressure decay tests and overhaul heaters failing these tests. Additionally, conduct repetitive operational testing of the combustion air pressure switch and replace any failing switches.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

JanAero Devices B-Series Combustion Heaters, Models B1500, B2030, B3040, and B4050 installed on aircraft, formerly owned by Janitrol, C&D, FL Aerospace, and Midland-Ross Corporation.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.