AD Amdt-39-9760
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Fokker | F28 Mark 0100 | Airworthiness Directives; Fokker Model F28 Mark 0100 Series Airplanes |
Unsafe Condition
Insufficient or no clearance between flexible oxygen hoses and adjacent structure or electrical wiring could result in chafing of the hoses, leading to uncontrollable loss of oxygen from the flightcrew oxygen system and potential oxygen presence in areas with ignition risk.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace certain flexible oxygen hoses in the flight compartment gangway and consoles with insulated hose assemblies to prevent chafing and oxygen leakage risks.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Model F28 Mark 0100 series airplanes with insufficient or no clearance between oxygen hoses and adjacent structure or electrical wiring.
AI-generated summary from the source AD text. Verify against the official source before acting.