AD Amdt-39-9553

final rule
Data completeness: 70%

Airworthiness Directives; Fokker Model F27 Mark 050 and Model F28 Mark 0100 Series Airplanes

AD Number
Amdt-39-9553
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 95-NM-70-AD
FR Citation
61 FR 14013

Applicability

TypeManufacturerModelDetails
aircraft Fokker F27 Mark 050 and Model F28 Mark 0100 Airworthiness Directives; Fokker Model F27 Mark 050 and Model F28 Mark 0100 Series Airplanes

Unsafe Condition

Circuit breaker terminal bolts that are too long could damage the insulation screen between adjacent rows of circuit breakers, leading to electrical arcing and loss of the associated electrical system, which could result in an electrical fire.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect to verify adequate clearance between the insulation screen and adjacent terminal bolts. Replace circuit breaker terminal bolts with new bolts if necessary.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Fokker Model F27 Mark 050 and Model F28 Mark 0100 series airplanes with circuit breaker panels where bolts may be too long.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain