AD Amdt-39-17186

final rule
Data completeness: 70%

Airworthiness Directives; Glasflugel Gliders

AD Number
Amdt-39-17186
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2012-0046
FR Citation
77 FR 55411

Applicability

TypeManufacturerModelDetails
aircraft Bell Various Airworthiness Directives; Glasflugel Gliders
aircraft Aviat Various Airworthiness Directives; Glasflugel Gliders

Unsafe Condition

Corrosion damage to the elevator control rod that could lead to failure of the elevator control rod, possibly resulting in loss of control of the glider.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect and replace the elevator control rod as necessary. Ensure the replacement control rod has an additional drain hole at the rod bottom between the forks.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 50 flight hours after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Glasflugel Models: Standard Libelle-201B, Club Libelle 205, Mosquito, and Kestrel gliders. Serial numbers: Club Libelle 205 (all S/Ns), Kestrel (all S/Ns except S/N 85, 110, and 125), Mosquito (all S/Ns), and Standard Libelle-201B (S/N 169).

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain