Airworthiness Directives; British Aerospace (Jetstream) Model 4101 Airplanes

AD Number
Amdt-39-11478
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 99-NM-302-AD
FR Citation
64 FR 72531

Applicability

TypeManufacturerModelDetails
aircraft British Aerospace (Jetstream) Model 4101 Airworthiness Directives; British Aerospace (Jetstream) Model 4101 Airplanes

Unsafe Condition

Loose or migrated levers of the elevator cable tension regulators, which could result in reduced controllability of the associated elevator.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a detailed visual inspection of the elevator cable tension regulator lever assembly within 7 weeks after the effective date, and repeat the inspection at intervals not to exceed 1,500 flight hours. If discrepancies are detected, replace the elevator cable tension regulator assembly with a new one. If no discrepancies are found, inspect the bolt and castellated nut for thread binding and take corrective action as necessary. Submit inspection reports as specified.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 7 weeks after the effective date

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

All British Aerospace (Jetstream) Model 4101 airplanes, certificated in any category.