AD Amdt-39-11478
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | British | Aerospace (Jetstream) Model 4101 | Airworthiness Directives; British Aerospace (Jetstream) Model 4101 Airplanes |
Unsafe Condition
Loose or migrated levers of the elevator cable tension regulators, which could result in reduced controllability of the associated elevator.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a detailed visual inspection of the elevator cable tension regulator lever assembly within 7 weeks after the effective date, and repeat the inspection at intervals not to exceed 1,500 flight hours. If discrepancies are detected, replace the elevator cable tension regulator assembly with a new one. If no discrepancies are found, inspect the bolt and castellated nut for thread binding and take corrective action as necessary. Submit inspection reports as specified.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 7 weeks after the effective date
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All British Aerospace (Jetstream) Model 4101 airplanes, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.