AD Amdt-39-11463
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | McDonnell Douglas | MD-11 | Airworthiness Directives; McDonnell Douglas Model MD-11 Series Airplanes |
Unsafe Condition
Damage to the wire assembly terminal lugs and power feeder cables due to accumulated effects over time from overheating of the power feeder cables on the G3 galley load control unit (GLCU), which could result in smoke and fire in the G3 galley.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 60 days after the effective date, perform a general visual inspection of the power feeder cables, terminal strip, fuseholder, and fuses of the GLCU within the No. 3 bay electrical power center. If damage is detected, take corrective actions, which may include replacing the power feeder cables, fuseholder, and/or fuses as applicable.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 60 days after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
McDonnell Douglas Model MD-11 series airplanes, as listed in McDonnell Douglas Alert Service Bulletin MD11-24A160, Revision 01, dated November 11, 1999; certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.