AD Amdt-39-11285
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | Industrie A300-600 and A310 | Airworthiness Directives; General Electric Company CF6-80A1/A3 and CF6-80C2A Series Turbofan Engines, Installed on Airbus Industrie A300-600 and A310 Series Airplanes |
| engine | General Electric | Company CF6-80A1/A3 and CF6-80C2A Series | Airworthiness Directives; General Electric Company CF6-80A1/A3 and CF6-80C2A Series Turbofan Engines, Installed on Airbus Industrie A300-600 and A310 Series Airplanes |
Unsafe Condition
Inadvertent thrust reverser deployment, which could result in loss of control of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a DPV pressure check for leakage and, if necessary, replace the DPV assembly with a serviceable one and perform an operational check of the thrust reverser, or deactivate the thrust reverser. If the thrust reverser is deactivated, revise the FAA-approved AFM to include performance penalties for certain takeoff conditions and revise the Emergency Procedures Section to include a flightcrew operational procedure for in-flight thrust reverser deployment indications.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
General Electric Company CF6-80A1/A3 and CF6-80C2A series turbofan engines installed on Airbus Industrie A300-600 and A310 series airplanes.