AD Amdt-39-11060
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | 737-100 | Airworthiness Directives; Boeing Model 737-100, -200, -300, -400, and -500 Series Airplanes |
Unsafe Condition
Chafing of the direct current (DC) powered float switch wiring insulation in the center fuel tank has occurred, leading to arcing from the wiring to the in-tank conduit, which could present an ignition source inside the fuel tank and consequent fire/explosion.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Remove the float switch and wiring, inspect the float switch wiring in the center fuel tank for discrepancies, and either reinstall the existing float switch and wiring or replace them with new components. Install Teflon sleeving over the wiring of the float switch. Alternatively, deactivate the float switch, implement specific fueling procedures, and install Caution signs.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Boeing Model 737-100, -200, -300, -400, and -500 series airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
This amendment adopts a new airworthiness directive (AD) that is applicable to certain Boeing Model 737-100, -200, -300, -400, and - 500 series airplanes. This action requires removal of the float switch and wiring and inspection of the float switch wiring in the center fuel tank to detect discrepancies, and either reinstallation of existing float switch and wiring, or replacement of the float switch and wiring with a new float switch and wiring. This action also requires installation of Teflon sleeving over the wiring of the float switch. In lieu of the above mentioned requirements, this AD requires deactivation of the float switch, accomplishment of specific fueling procedures, and installation of Caution signs. This amendment is prompted by a report indicating that chafing of the direct current (DC) powered float switch wiring insulation in the center fuel tank has occurred on several airplanes. The actions specified in this AD are intended to detect and correct such chafing and the resultant arcing from the wiring to the in-tank conduit, which could present an ignition source inside the fuel tank and consequent fire/explosion.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 64, Number 41 (Wednesday, March 3, 1999)]
[Rules and Regulations]
[Pages 10213-10216]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 99-5042]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. 98-NM-375-AD; Amendment 39-11060; AD 99-05-12]
RIN 2120-AA64
Airworthiness Directives; Boeing Model 737-100, -200, -300, -400,
and -500 Series Airplanes
AGENCY: Federal Aviation Administration, DOT.
ACTION: Final rule; request for comments.
-----------------------------------------------------------------------
SUMMARY: This amendment adopts a new airworthiness directive (AD) that
is applicable to certain Boeing Model 737-100, -200, -300, -400, and -
500 series airplanes. This action requires removal of the float switch
and wiring and inspection of the float switch wiring in the center fuel
tank to detect discrepancies, and either reinstallation of existing
float switch and wiring, or replacement of the float switch and wiring
with a new float switch and wiring. This action also requires
installation of Teflon sleeving over the wiring of the float switch. In
lieu of the above mentioned requirements, this AD requires deactivation
of the float switch, accomplishment of specific fueling procedures, and
installation of Caution signs. This amendment is prompted by a report
indicating that chafing of the direct current (DC) powered float switch
wiring insulation in the center fuel tank has occurred on several
airplanes. The actions specified in this AD are intended to detect and
correct such chafing and the resultant arcing from the wiring to the
in-tank conduit, which could present an ignition source inside the fuel
tank and consequent fire/explosion.
DATES: Effective March 18, 1999.
The incorporation by reference of certain publications listed in
the regulations is approved by the Director of the Federal Register as
of May 3, 1999.
Comments for inclusion in the Rules Docket must be received on or
before May 3, 1999.
ADDRESSES: Submit comments in triplicate to the Federal Aviation
Administration (FAA), Transport Airplane Directorate, ANM-114,
Attention: Rules Docket No. 98-NM-375-AD, 1601 Lind Avenue, SW.,
Renton, Washington 98055-4056.
The service information referenced in this AD may be obtained from
Boeing Commercial Airplane Group, P.O. Box 3707, Seattle, Washington
98124-2207. This information may be examined at the FAA, Transport
Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at
the Office of the Federal Register, 800 North Capitol Street, NW.,
suite 700, Washington, DC.
FOR FURTHER INFORMATION CONTACT: Dorr M. Anderson, Aerospace Engineer,
Propulsion Branch, ANM-140S, FAA, Transport Airplane Directorate,
Seattle Aircraft Certification Office, 1601 Lind Avenue, SW., Renton,
Washington
[[Page 10214]]
98055-4056; telephone (425) 227-2684; fax (425) 227-1181.
SUPPLEMENTARY INFORMATION: The FAA has received a report indicating
that chafing of the direct current (DC) powered float switch wiring
insulation in the center fuel tank has occurred on eight Boeing Model
737-200 series airplanes. These airplanes had accumulated between
32,000 and 85,000 total flight hours. Such chafing may be attributed to
vibrational contact between the conduit and float switch wiring.
Chafing of the float switch wiring insulation in the center fuel tank,
if not corrected, could result in arcing from the wiring to the in-tank
conduit, which could present an ignition source inside the fuel tank
and consequent fire/explosion.
Similar Airplanes
The center fuel tank float switch installation on certain Boeing
Model 737-100, -300, -400, and -500 series airplanes is similar to that
on the affected Boeing Model 737-200 series airplanes. Therefore, the
FAA has determined that all of these models may be subject to the
unsafe condition identified in this AD.
Explanation of Relevant Service Information
The FAA has reviewed and approved Boeing Alert Service Bulletin
737-28A1132, dated December 2, 1998, and Revision 1, dated January 15,
1999. The alert service bulletin describes the following procedures:
1. Removing the float switch and wiring from the center fuel tank,
performing a visual inspection of the float switch wiring to detect
discrepancies (i.e., evidence of electrical arcing, exposure of the
copper conductor, presence or scent of fuel on the electrical wires, or
worn insulation), and performing corrective actions. (The major
corrective actions include measuring the resistance between the wires
and the float switch housing; reusing the existing float switch and
wiring or replacing the discrepant float switch and wiring with a new
float switch and wiring; installing double Teflon sleeving over the
wiring of the float switch; and replacing any section of electrical
conduit where arcing or leaking has occurred with a new section.)
2. Deactivating the float switch (i.e., cut the two wires for the
float switch at the splices on the front spar and cap and stow the four
wire ends; or cut, stow, and splice the two wires for the float switch
at the splices on the front spar), painting a Caution that shows a
conservative maximum fuel capacity for the center tank on the underside
of the right-hand wing near the fueling station door, and installing an
INOP placard on the fueling panel, as applicable.
3. Performing modified fueling procedures following deactivation of
the float switch.
The FAA also has reviewed Boeing Telex M-7200-98-04486, dated
December 1, 1998, which describes two manual fueling procedures for the
center fuel tank after the float switch has been deactivated by either
of the methods described above.
Accomplishment of the actions specified in the alert service
bulletin and telex is intended to adequately address the identified
unsafe condition.
Explanation of the Requirements of the Rule
Since an unsafe condition has been identified that is likely to
exist or develop on other airplanes of the same type design, this AD is
being issued to detect and correct chafing of the float switch wiring
insulation in the center fuel tank and the resultant arcing from the
wiring to the conduit, which could present an ignition source inside
the fuel tank and consequent fire/explosion. This AD requires
accomplishment of the actions specified in the alert service bulletin
and telex described previously; except as discussed below.
This AD also includes a provision that supersedes the FAA-approved
Master Minimum Equipment List (MMEL), in that it allows dispatch of the
airplane with the center fuel tank float switch deactivated in
accordance with Boeing Alert Service Bulletin 737-28A1132, until
replacement float switches and wiring are available for installation.
The FAA-approved MMEL allows dispatch of the airplane with the
``Pressure Fueling System'' inoperative up to 10 days. (The float
switch wiring circuit is part of the ``Pressure Fueling System.'') The
FAA has been notified by the manufacturer that it will take
approximately 18 months to obtain required parts from the issuance of
Boeing Alert Service Bulletin 737-28-A1132, dated December 2, 1998. The
FAA finds that the 18-month period will accommodate the time necessary
for affected operators to order, obtain, and install the necessary
parts required for the replacement of the float switch, without
adversely affecting safety. The FAA also finds that such a provision
will eliminate schedule disruptions. Absence of such operational relief
could create a burden for operators if required parts were not readily
available at certain airports or locations.
Differences Between the AD and the Relevant Alert Service Bulletin
Operators should note that the applicability of this AD affects
certain Boeing Model 737-100, -200, -300, -400, and -500 series
airplanes, on which the center wing tanks are activated; excluding
those airplanes equipped with center wing tank volumetric topoff
systems, or alternate current (AC) powered center tank float switches.
This differs from the effectivity listing of the referenced alert
service bulletin. While it is assumed that an operator will know the
models of airplanes that it operates, there is a potential that the
operator will not know or be aware of specific items that are installed
on its airplanes. For this reason, it may be necessary for operators to
check their records to determine if center wing tank volumetric topoff
systems, or alternate current (AC) powered center tank float switches
have been installed on their fleet of airplanes. Such a check will
identify airplanes that are subject to the unsafe condition of this AD.
Operators also should note that, although the referenced alert
service bulletin contains modified fueling procedures following
deactivation of the float switch, this AD requires accomplishment of
the manual fueling procedures specified in Boeing Telex M-7200-98-
04486, as described above. The FAA finds that the procedures specified
in the telex are more detailed than those in the alert service
bulletin. The procedures specified in the telex provide step-by-step
fueling instructions for airplanes with a deactivated center tank float
switch to minimize the possibility of fuel spills.
Prior to utilizing these fueling procedures, this AD requires
operators to ensure that airplane fueling crews are properly trained in
accordance with the procedures specified in the telex, or the
procedures approved by the FAA. Prior to each occurrence of fueling the
airplane, this AD requires a check to verify that the fueling panel
center tank quantity indicator is operative, and replacement of the
indicator with a serviceable indicator, if necessary. Accomplishment of
such training and a check will provide the proper safeguards necessary
to minimize fuel spills during airplane fueling.
Interim Action
The FAA is considering further rulemaking action to supersede this
AD to require, within 18 months after accomplishment of the actions
specified in paragraphs (c) and (d) of this AD, and within 15,000
flight hours after
[[Page 10215]]
reinstalling any existing float switch having worn insulation and
double Teflon sleeving, replacement of the float switch and wiring with
a new float switch and wiring. However, the planned compliance time for
these actions is sufficiently long so that prior notice and time for
public comment will be practicable.
Determination of Rule's Effective Date
Since a situation exists that requires the immediate adoption of
this regulation, it is found that notice and opportunity for prior
public comment hereon are impracticable, and that good cause exists for
making this amendment effective in less than 30 days.
Comments Invited
Although this action is in the form of a final rule that involves
requirements affecting flight safety and, thus, was not preceded by
notice and an opportunity for public comment, comments are invited on
this rule. Interested persons are invited to comment on this rule by
submitting such written data, views, or arguments as they may desire.
Communications shall identify the Rules Docket number and be submitted
in triplicate to the address specified under the caption ADDRESSES. All
communications received on or before the closing date for comments will
be considered, and this rule may be amended in light of the comments
received. Factual information that supports the commenter's ideas and
suggestions is extremely helpful in evaluating the effectiveness of the
AD action and determining whether additional rulemaking action would be
needed.
Comments are specifically invited on the overall regulatory,
economic, environmental, and energy aspects of the rule that might
suggest a need to modify the rule. All comments submitted will be
available, both before and after the closing date for comments, in the
Rules Docket for examination by interested persons. A report that
summarizes each FAA-public contact concerned with the substance of this
AD will be filed in the Rules Docket.
Commenters wishing the FAA to acknowledge receipt of their comments
submitted in response to this rule must submit a self-addressed,
stamped postcard on which the following statement is made: ``Comments
to Docket Number 98-NM-375-AD.'' The postcard will be date stamped and
returned to the commenter.
Regulatory Impact
The regulations adopted herein will not have substantial direct
effects on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government. Therefore, in
accordance with Executive Order 12612, it is determined that this final
rule does not have sufficient federalism implications to warrant the
preparation of a Federalism Assessment.
The FAA has determined that this regulation is an emergency
regulation that must be issued immediately to correct an unsafe
condition in aircraft, and that it is not a ``significant regulatory
action'' under Executive Order 12866. It has been determined further
that this action involves an emergency regulation under DOT Regulatory
Policies and Procedures (44 FR 11034, February 26, 1979). If it is
determined that this emergency regulation otherwise would be
significant under DOT Regulatory Policies and Procedures, a final
regulatory evaluation will be prepared and placed in the Rules Docket.
A copy of it, if filed, may be obtained from the Rules Docket at the
location provided under the caption ADDRESSES.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, pursuant to the authority delegated to me by the
Administrator, the Federal Aviation Administration amends part 39 of
the Federal Aviation Regulations (14 CFR part 39) as follows:
PART 39--AIRWORTHINESS DIRECTIVES
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
2. Section 39.13 is amended by adding the following new
airworthiness directive:
99-05-12 Boeing: Amendment 39-11060. Docket 98-NM-375-AD.
Applicability: Model 737-100, -200, -300, -400, and -500 series
airplanes, on which the center wing tanks are activated; excluding
those airplanes equipped with center wing tank volumetric topoff
systems, or alternate current (AC) powered center tank float
switches; certificated in any category.
Note 1: This AD applies to each airplane identified in the
preceding applicability provision, regardless of whether it has been
modified, altered, or repaired in the area subject to the
requirements of this AD. For airplanes that have been modified,
altered, or repaired so that the performance of the requirements of
this AD is affected, the owner/operator must request approval for an
alternative method of compliance in accordance with paragraph (f) of
this AD. The request should include an assessment of the effect of
the modification, alteration, or repair on the unsafe condition
addressed by this AD; and, if the unsafe condition has not been
eliminated, the request should include specific proposed actions to
address it.
Compliance: Required as indicated, unless accomplished
previously.
To detect and correct chafing of the float switch wiring
insulation in the center fuel tank and the resultant arcing from the
wiring to the in-tank conduit, which could present an ignition
source inside the fuel tank and consequent fire/explosion,
accomplish the following:
(a) Prior to the accumulation of 30,000 total flight hours, or
within 30 days after the effective date of this AD, whichever occurs
later, accomplish the requirements of paragraph (b) or (c) of this
AD.
(b) Remove the fueling float switch and wiring from the center
fuel tank and perform a visual inspection of the float switch wiring
to detect discrepancies (i.e., evidence of electrical arcing,
exposure of the copper conductor, presence or scent of fuel on the
electrical wires, or worn insulation), in accordance with Part 1 of
the Accomplishment Instructions of Boeing Alert Service Bulletin
737-28A1132, dated December 2, 1998, or Revision 1, dated January
15, 1999. Pay particular attention to the wire bundle where it
passes through the wing pylon vapor seals and under the wire bundle
clamps.
(1) If no discrepancy is detected, prior to further flight,
accomplish either paragraph (b)(1)(i) or (b)(1)(ii) of this AD.
(i) Measure the resistance between the wires and the float
switch housing, in accordance with the alert service bulletin.
(A) If the resistance is less than 200 megohms, prior to further
flight, replace the float switch with a new float switch, and
install double Teflon sleeving over the wiring of the float switch,
in accordance with the alert service bulletin; except, if the
replacement float switch and wiring are not available, prior to
further flight, accomplish the requirements specified in paragraphs
(c) and (d) of this AD.
(B) If the resistance is greater than or equal to 200 megohms,
prior to further flight, blow dirt out of the conduit, install
double Teflon sleeving over the wiring of the float switch, and
reinstall the existing float switch, in accordance with the alert
service bulletin.
(ii) Replace the float switch and wiring with a new float switch
and wiring, and install double Teflon sleeving over the wiring of
the float switch, in accordance with the alert service bulletin;
except, if the replacement float switch and wiring are not
available, prior to further flight, accomplish the requirements
specified in paragraphs (c) and (d) of this AD.
(2) If any worn insulation is detected, and if no copper
conductor is exposed, and if no evidence of arcing is detected;
accomplish the requirements specified in either paragraph (b)(1)(i)
or (b)(1)(ii) of this AD.
[[Page 10216]]
(3) If any electrical arcing or exposed copper conductor is
detected, prior to further flight, accomplish either paragraph
(b)(3)(i) or (b)(3)(ii) of this AD.
(i) Replace any section of the electrical conduit where the
arcing occurred with a new section, in accordance with the alert
service bulletin, and accomplish the requirements specified in
paragraph (b)(1)(ii) of this AD.
(ii) Perform a visual inspection to detect fuel leaks of the
electrical conduit, in accordance with the alert service bulletin.
(A) If no fuel leak is detected, prior to further flight,
accomplish the requirements specified in paragraph (b)(1)(ii) of
this AD. Repeat the inspection required by paragraph (b)(3)(ii) of
this AD thereafter at intervals not to exceed 1,500 flight hours,
until the replacement required by paragraph (b)(3)(ii)(B) of this AD
is accomplished.
(B) If any fuel leak is detected, prior to further flight,
replace any section of the electrical conduit where the leak is with
a new section, in accordance with the alert service bulletin. Prior
to further flight after accomplishment of the replacement,
accomplish the requirements specified in paragraph (b)(1)(ii) of
this AD. Accomplishment of electrical conduit replacement
constitutes terminating action for the repetitive inspection
requirements of paragraph (b)(3)(ii)(A) of this AD.
(4) If any presence or scent of fuel on the electrical wires is
detected, prior to further flight, locate the source of the leak and
replace the damaged conduit with a new conduit, in accordance with
the alert service bulletin; and accomplish the requirements
specified in either paragraph (b)(1)(i) or (b)(1)(ii) of this AD,
unless accomplished previously in accordance with paragraph (b)(1),
(b)(2), or (b)(3) of this AD.
(c) Accomplish the requirements specified in either paragraph
(c)(1) or (c)(2) of this AD, in accordance with Part 2 of the
Accomplishment Instructions of Boeing Alert Service Bulletin 737-
28A1132, dated December 2, 1998, or Revision 1 dated January 15,
1999.
(1) Deactivate the center tank float switch (i.e., cut the two
wires for the float switch at the splices on the front spar and cap
and stow the four wire ends); paint a Caution that shows a
conservative maximum fuel capacity for the center tank on the
underside of the right-hand wing near the fueling station door; and
install an INOP placard on the fueling panel.
(2) Deactivate the center tank float switch (i.e., cut, stow,
and splice the two wires for the float switch at the splices on the
front spar), and paint a Caution that shows a conservative maximum
fuel capacity for the center tank on the underside of the right-hand
wing near the fueling station door.
(d) For airplanes on which the requirements specified in
paragraph (c) of this AD have been accomplished: Accomplish the
requirements specified in paragraph (d)(1), (d)(2), and (d)(3) of
this AD.
(1) Operators must ensure that airplane fueling crews are
properly trained in accordance with the procedures specified in
Boeing Telex M-7200-98-04486, dated December 1, 1998, or procedures
approved by the FAA. This one-time training must be accomplished
prior to utilizing the procedures specified in paragraph (d)(3) of
this AD.
(2) Prior to fueling the airplane, perform a check to verify
that the fueling panel center tank quantity indicator is operative.
Repeat this check thereafter prior to fueling the airplane. If the
fueling panel center tank quantity indicator is not operative, prior
to further flight, replace the fueling panel center tank quantity
indicator with a serviceable part.
(3) One of the two manual fueling procedures for the center fuel
tank must be used for each fueling occurrence, in accordance with
Boeing Telex M-7200-98-04486, dated December 1, 1998, or a method
approved by the FAA.
Note 2: For the purposes of this AD, the term ``the FAA,'' is
defined in paragraph (d) of this AD as ``the cognizant Principal
Maintenance Inspector (PMI).''
Note 3: Where there are differences between the Boeing Alert
Service Bulletin 737-28A1132 and this AD, the AD prevails.
(e) Dispatch with the center fuel tank float switch deactivated,
in accordance with Boeing Alert Service Bulletin 737-28A1132, dated
December 2, 1998, or Revision 1, dated January 15, 1999, is allowed
until replacement float switches and wiring are available for
installation. Where there are differences between the Master Minimum
Equipment List (MMEL) and the AD, the AD prevails.
(f) An alternative method of compliance or adjustment of the
compliance time that provides an acceptable level of safety may be
used if approved by the Manager, Seattle Aircraft Certification
Office (ACO), FAA, Transport Airplane Directorate. Operators shall
submit their requests through an appropriate FAA PMI, who may add
comments and then send it to the Manager, Seattle ACO.
Note 4: Information concerning the existence of approved
alternative methods of compliance with this AD, if any, may be
obtained from the Seattle ACO.
(g) Special flight permits may be issued in accordance with
sections 21.197 and 21.199 of the Federal Aviation Regulations (14
CFR 21.197 and 21.199) to operate the airplane to a location where
the requirements of this AD can be accomplished.
(h) Except as provided by paragraphs (d)(1) and (d)(2) of this
AD, the actions shall be done in accordance with Boeing Alert
Service Bulletin 737-28A1132, dated December 2, 1998; Boeing Alert
Service Bulletin 737-28A1132, Revision 1, dated January 15, 1999;
and Boeing Telex M-7200-98-04486, dated December 1, 1998, as
applicable. This incorporation by reference was approved by the
Director of the Federal Register in accordance with 5 U.S.C. 552(a)
and 1 CFR part 51. Copies may be obtained from Boeing Commercial
Airplane Group, P.O. Box 3707, Seattle, Washington 98124-2207.
Copies may be inspected at the FAA, Transport Airplane Directorate,
1601 Lind Avenue, SW., Renton, Washington; or at the Office of the
Federal Register, 800 North Capitol Street, NW., suite 700,
Washington, DC.
(i) This amendment becomes effective on March 18, 1999.
Issued in Renton, Washington, on February 23, 1999.
Darrell M. Pederson,
Acting Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 99-5042 Filed 3-2-99; 8:45 am]
BILLING CODE 4910-13-U
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.