AD Amdt-39-10977
Unsafe Condition
Improper swaging of amp fittings on the end of the stainless steel breakaway housing could result in the amp fittings coming off, leading to an unintentional partial breakaway of the main chute and interference with the deployment of the reserve parachute.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the amp fittings on the end of the breakaway housing for proper swaging. Re-swage any incorrectly swaged fittings using the Nicopress or Swage-It swaging tool.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
The Uninsured Relative Workshop Inc. (Relative Workshop) vector parachute systems manufactured between January 1, 1996, and September 10, 1998.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.