AD Amdt-39-10955

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 200) Series Airplanes

AD Number
Amdt-39-10955
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 98-NM-330-AD
FR Citation
63 FR 70319

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 200) Series Airplanes

Unsafe Condition

Chafing or cracking of electrical wiring conduits in the center fuel tank and inadequate clearance between tube assemblies and adjacent structures, which could result in electrical arcing and consequent fire or explosion in the center fuel tank.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a one-time visual inspection to detect chafing or cracking of all electrical wiring conduits in the center fuel tank and inadequate clearance between tube assemblies and adjacent structures. Take corrective actions, if necessary, including repairing or replacing damaged conduits and relocating/reforming conduits to provide adequate clearance. Install a bracket support kit to reinforce the right wing crossflow shutoff valve conduit.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 200) series airplanes, serial numbers 7003 through 7246 inclusive.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain