AD Amdt-39-10895
Unsafe Condition
Water penetration into the elevator and trim tab due to inadequate drainage can lead to delamination of the structure, resulting in elevator imbalance and flutter.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the elevator and trim tab for water. Ensure necessary drain holes are installed and existing holes are open. Drill any required drain holes and open closed holes. If more than 1/2 liter of water is found, verify that the elevator's weight, residual momentum, and glider's center of gravity are within flight manual limits, and adjust as necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Burkhart GROB Luft-und Raumfahrt GmbH Model G 109B gliders
AI-generated summary from the source AD text. Verify against the official source before acting.