Airworthiness Directives; British Aerospace Jetstream Models 3101 and 3201 Airplanes

AD Number
Amdt-39-10833
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 98-CE-28-AD
FR Citation
63 FR 55325

Applicability

TypeManufacturerModelDetails
aircraft British Aerospace Jetstream Models 3101 and 3201 Airworthiness Directives; British Aerospace Jetstream Models 3101 and 3201 Airplanes

Unsafe Condition

Failure of the ground inhibit relay while in the energized position, caused by the current design, could result in failure of the stall warning system and possible loss of control of the airplane in certain situations if the crew was not aware of the system failure.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Remove the ground inhibit time delay and the ground test relay from the stall warning and protection system. Rewire part of the stall warning and protection system to ensure system reliability after relay removal.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

British Aerospace Jetstream Models 3101 and 3201 airplanes equipped with the ground inhibit function (Modification JM7813A (SB 27-JM7813A) or JM7813B).

AI-generated summary from the source AD text. Verify against the official source before acting.