Airworthiness Directives; Dornier Model 328-100 Series Airplanes

AD Number
Amdt-39-10790
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 98-NM-96-AD
FR Citation
63 FR 50505

Applicability

TypeManufacturerModelDetails
aircraft Dornier Model 328-100 Series Airworthiness Directives; Dornier Model 328-100 Series Airplanes

Unsafe Condition

Overheating of electrical connections in the DC power unit 1VE could result in electrical arcing and consequent fire.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the DC power unit 1VE for correct electrical connections and stud nut torque. Replace the unit with a modified version if required. Perform corrective actions as necessary.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Dornier Model 328-100 series airplanes with certain configurations requiring inspection or replacement of DC power unit 1VE.

AI-generated summary from the source AD text. Verify against the official source before acting.