Unsafe Condition
Overheating of electrical connections in the DC power unit 1VE could result in electrical arcing and consequent fire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the DC power unit 1VE for correct electrical connections and stud nut torque. Replace the unit with a modified version if required. Perform corrective actions as necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 series airplanes with certain configurations requiring inspection or replacement of DC power unit 1VE.