AD Amdt-39-10779
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dornier | Model 328-100 Series | Airworthiness Directives; Dornier Model 328-100 Series Airplanes |
Unsafe Condition
Failure of normal extension and retraction of the landing gear, which could result in collapse of the main landing gear upon landing.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace certain landing gear proximity sensor electrical units (PSEU) with improved units.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 series airplanes with certain landing gear proximity sensor electrical units (PSEU)
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain