Unsafe Condition
Cracking of elevator hinge rib 1 of the horizontal stabilizer could occur if the gust damper of the elevator control system discharges and allows the elevator to move freely in ground gust conditions, resulting in damage to the structural attachment of the elevator and consequent reduced controllability.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Conduct a one-time inspection of the gust damper to determine if it is properly charged and inspect the horizontal stabilizer for cracking of elevator hinge rib 1. Perform corrective action if necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
British Aerospace Model BAe 146-200A series airplanes
AI-generated summary from the source AD text. Verify against the official source before acting.