AD Amdt-39-10618
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dornier | Model 328-100 Series | Airworthiness Directives; Dornier Model 328-100 Series Airplanes |
Unsafe Condition
Electrical short circuits of the contact points and power relays on circuit breaker panels 10VE and 11VE could result in increased risk of smoke and fire damage in the flight compartment.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Conduct a one-time inspection of circuit breaker panels 10VE and 11VE to detect discrepancies; perform follow-on corrective actions including modification of contact points and installation of a high capacity fuse. Replace power relays 32HB and 36HB on relay panel 22VE with new parts.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 series airplanes subject to mandatory continuing airworthiness information by a foreign civil airworthiness authority.
AI-generated summary from the source AD text. Verify against the official source before acting.