AD Amdt-39-10583

final rule
Data completeness: 60%

Airworthiness Directives; Lucas Air Equipment Electric Hoists

AD Number
Amdt-39-10583
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 98-SW-04-AD
FR Citation
63 FR 31616

Unsafe Condition

Cable failures caused by dynamic overload on the winding-up limit due to uncontrolled excessive speed of the cable, which is normally regulated by the automatic speed-reducing mechanism or the operator.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Visually inspect the cable for damage before the next hoist operation, blanking (plugging) the electronic control box upper vent, and performing an end-of-travel procedure before each hoist operation.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further hoist operation

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Lucas Air Equipment electric hoists installed on Eurocopter France SA-360 and SA-365 helicopters

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.