AD Amdt-39-10431

final rule
Data completeness: 70%

Airworthiness Directives; GKN Westland Helicopters Limited WG-30 Series 100 and 100-60 Helicopters

AD Number
Amdt-39-10431
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 97-SW-28-AD
FR Citation
63 FR 15756

Applicability

TypeManufacturerModelDetails
aircraft GKN Westland Airworthiness Directives; GKN Westland Helicopters Limited WG-30 Series 100 and 100-60 Helicopters

Unsafe Condition

Failure of a main rotor head tie-bar due to exceeding power-off transient rotor speed limitations could result in loss of a main rotor blade and subsequent loss of control of the helicopter.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Conduct an initial visual inspection and replace all main rotor head tie-bars if necessary. Thereafter, replace each tie-bar at intervals not exceeding 220 hours time-in-service with an airworthy tie-bar.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

GKN Westland Helicopters Limited WG-30 series 100 and 100-60 helicopters.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain