AD Amdt-39-10407
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | 747-400 | Airworthiness Directives; Boeing Model 747-400 Series Airplanes |
Unsafe Condition
Inadequate clearance between the galley power feeder wiring and passenger oxygen system tubing could result in a fire in the ceiling area above the door 4 galley due to chafing of wiring on oxygen system tubing.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the separation between the galley power feeder and static ground wiring and adjacent passenger oxygen system tubing in the forward ceiling area above the door 4 galley. Reroute wiring and install clamps and sleeves if necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Boeing Model 747-400 series airplanes with certain configurations requiring the specified wiring and oxygen system tubing arrangement.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain