Airworthiness Directives; Boeing Model 747-400 Series Airplanes

AD Number
Amdt-39-10407
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 97-NM-65-AD
FR Citation
63 FR 13497

Applicability

TypeManufacturerModelDetails
aircraft Boeing 747-400 Airworthiness Directives; Boeing Model 747-400 Series Airplanes

Unsafe Condition

Inadequate clearance between the galley power feeder wiring and passenger oxygen system tubing could result in a fire in the ceiling area above the door 4 galley due to chafing of wiring on oxygen system tubing.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the separation between the galley power feeder and static ground wiring and adjacent passenger oxygen system tubing in the forward ceiling area above the door 4 galley. Reroute wiring and install clamps and sleeves if necessary.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Boeing Model 747-400 series airplanes with certain configurations requiring the specified wiring and oxygen system tubing arrangement.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain