AD Amdt-39-10395
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dassault | Mystere Falcon 900 | Airworthiness Directives; Dassault Model Mystere Falcon 900 Series Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; Dassault Model Mystere Falcon 900 Series Airplanes |
Unsafe Condition
Overheating of the water heaters for the galley or the washbasin could result in damage to the water heater and nearby electrical wiring, and consequent smoke in the cabin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace water heater control relays with improved relays having high-power contactors; add a testing and monitoring circuit for each contactor; install improved electrical bonding of the potable water tank.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dassault Aviation Model Mystere Falcon 900 series airplanes subject to mandatory continuing airworthiness information by a foreign civil airworthiness authority.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗