AD Amdt-39-10131
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Raytheon | Aircraft Company Models 1900 | Airworthiness Directives; Raytheon Aircraft Company Models 1900, 1900C, and 1900D Airplanes |
Unsafe Condition
Moisture accumulating and freezing in the airstair door handle and latch housing could result in the door freezing shut and passengers not being able to evacuate the airplane in an emergency situation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install lubrication fittings in the airstair door handle and latch housing mechanisms to prevent moisture accumulation and freezing. Correct model and serial number references in applicability section of AD 97-15-13.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Raytheon Aircraft Company Models 1900, 1900C, and 1900D airplanes, including certain Model 1900C serial number airplanes previously misreferenced as Model 1900D in AD 97-15-13.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain