AD 99-22-05

final rule
Data completeness: 70%

Airworthiness Directives; Short Brothers Model SD3-60 Series Airplanes

AD Number
99-22-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
99-NM-52-AD
FR Citation
Federal Register: October 22, 1999 (Volume 64, Number 204)

Applicability

TypeManufacturerModelDetails
aircraft Short Brothers PLC SD3-60 Airworthiness Directives; Short Brothers Model SD3-60 Series Airplanes

Unsafe Condition

Failure of the elevator trim cable due to fatigue cracking, which could result in reduced controllability of the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a visual inspection of the elevator trim cables for wear damage or broken wires within 12 months after the effective date. Replace damaged cables with 7x19 cables. Replace all 7x7 cables with 7x19 cables before 10,000 total flight hours or within 12 months after the effective date, whichever is later. Repeat inspections every 12 months or 2,400 flight hours.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 12 months after the effective date (November 26, 1999) for initial inspection and cable replacement. Repeat inspections within 12 months or 2,400 flight hours.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Short Brothers Model SD3-60 series airplanes, all serial numbers.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain