AD 99-09-07
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Centrair | 101 | Airworthiness Directives; S.N. CENTRAIR 101 Series Gliders |
| aircraft | Centrair | 101A | Airworthiness Directives; S.N. CENTRAIR 101 Series Gliders |
| aircraft | Centrair | 101AP | Airworthiness Directives; S.N. CENTRAIR 101 Series Gliders |
| aircraft | Centrair | 101P | Airworthiness Directives; S.N. CENTRAIR 101 Series Gliders |
Unsafe Condition
Elevator flight control interference caused by an unsecured battery discharge warning device, which could result in reduced or loss of glider control.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install an attachment lug (part number $Y986A or FAA-approved equivalent) to the supporting bracket to secure the battery discharge warning device. Accomplish installation in accordance with CENTRAIR Service Bulletin No. 101-19, Revision 1, dated May 20, 1997.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 3 calendar months after the effective date of this AD (June 7, 1999)
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Centrair models 101, 101A, 101P, and 101AP gliders with modification 101-24 incorporated and without modification 101-21 incorporated.
AI-generated summary from the source AD text. Verify against the official source before acting.