Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Saab AB, Saab Aerosystems | SAAB 2000 | Airworthiness Directives; Saab Model SAAB 2000 Series Airplanes |
Unsafe Condition
Short circuiting between the flight attendant's floormat heater and the floor panel could cause overheating of the floormat heater and lead to smoke or fire in the airplane cabin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Deactivate the flight attendant's floormat heater by disconnecting electrical cable HW71-20 between the floormat heater and the floor panel, or by removing fuse 17HW (1) on panel 306VU, in accordance with specified Saab service bulletins. Alternative methods of compliance may be approved by the FAA.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 14 days after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Saab Model SAAB 2000 series airplanes, serial numbers -004 through -064 inclusive