AD 98-20-24
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | 328 Support Services GmbH | 328-100 | Airworthiness Directives; DORNIER LUFTFAHRT GmbH Model 328-100 Series Airplanes |
Unsafe Condition
Overheating of electrical connections in DC power unit 1VE could result in electrical arcing and consequent fire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a one-time visual inspection of DC power unit 1VE to verify correct installation of electrical connections and torque inspection of stud nuts. Correct discrepancies prior to further flight. Replace existing DC power unit 1VE with a modified unit for affected airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 10 days after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
DORNIER LUFTFAHRT GmbH Model 328-100 series airplanes listed in Dornier Alert Service Bulletins ASB-328-24-018 (dated August 5, 1997) or ASB-328-24-021 (dated November 25, 1997)
AI-generated summary from the source AD text. Verify against the official source before acting.