Airworthiness Directives; DORNIER LUFTFAHRT GmbH Model 328-100 Series Airplanes

AD Number
98-20-24
Status
final_rule
Effective Date
Product Category
aircraft
Docket
98-NM-96-AD
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft 328 Support Services GmbH 328-100 Airworthiness Directives; DORNIER LUFTFAHRT GmbH Model 328-100 Series Airplanes

Unsafe Condition

Overheating of electrical connections in DC power unit 1VE could result in electrical arcing and consequent fire.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a one-time visual inspection of DC power unit 1VE to verify correct installation of electrical connections and torque inspection of stud nuts. Correct discrepancies prior to further flight. Replace existing DC power unit 1VE with a modified unit for affected airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 10 days after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

DORNIER LUFTFAHRT GmbH Model 328-100 series airplanes listed in Dornier Alert Service Bulletins ASB-328-24-018 (dated August 5, 1997) or ASB-328-24-021 (dated November 25, 1997)