AD 98-18-03

final rule
Data completeness: 70%

Airworthiness Directives; McDonnell Douglas Model MD-90-30 Series Airplanes

AD Number
98-18-03
Status
final_rule
Effective Date
Product Category
aircraft
Docket
98-NM-136-AD
FR Citation
(Federal Register: August 27, 1998 (Volume 63, Number 166))

Applicability

TypeManufacturerModelDetails
aircraft The Boeing Company MD-90-30 Airworthiness Directives; McDonnell Douglas Model MD-90-30 Series Airplanes

Unsafe Condition

Electrical short circuit of the wiring of the strake ice protection system (SIPS), which could result in a fire in the electrical and electronic compartment of the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Modify the wiring of the SIPS and perform a resistance test of the electrical insulation in accordance with McDonnell Douglas Alert Service Bulletin MD90-30A021. If any strake heating wiring fails the resistance test, replace the discrepant wiring with new wiring and repeat the resistance test.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 180 days after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Model MD-90-30 series airplanes listed in McDonnell Douglas Alert Service Bulletin MD90-30A021, dated March 31, 1998; certificated in any category.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain