AD 98-17-08
Unsafe Condition
Ineffective or absent sealwires in the fireguards of the engine fire shut-off system could result in in-flight engine shutdown due to inadvertent closure of the fire shut-off valves.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 30 days after the effective date, inspect the engine fire shut-off system sealwire for discrepancies per Part I of Fokker Service Bulletin F28/76-20. Repair any discrepancies before further flight. Repeat inspections at intervals not exceeding 3,000 flight hours.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 30 days after the effective date of this AD, and thereafter at intervals not to exceed 3,000 flight hours.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Model F.28 Mark 1000, 2000, 3000, and 4000 series airplanes; all serial numbers.
AI-generated summary from the source AD text. Verify against the official source before acting.