Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Piaggio Aero Industries S.p.A. | P-180 | Airworthiness Directives; Industrie Aeronautiche e Meccaniche Model Piaggio P-180 Airplanes. |
Unsafe Condition
Water leakage from the lavatory water duct system could collect in the fuselage, freeze in cold weather conditions, and cause the rudder control system to jam.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Accomplish a leakage check of all lavatory water tube/hose connections within 3 calendar months after the effective date. If leakage is found, correct the installation prior to further flight in accordance with Piaggio Service Bulletin SB-80-0096.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 3 calendar months after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Model Piaggio P-180 airplanes, serial numbers 1002, 1004, 1006 through 1017, 1019, and 1021 through 1030, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.