AD 98-13-07

final rule
Data completeness: 70%

Airworthiness Directives; Industrie Aeronautiche e Meccaniche Model Piaggio P-180 Airplanes.

AD Number
98-13-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
98-CE-21-AD
FR Citation
Federal Register: June 19, 1998 (Volume 63, Number 118)

Applicability

TypeManufacturerModelDetails
aircraft Piaggio Aero Industries S.p.A. P-180 Airworthiness Directives; Industrie Aeronautiche e Meccaniche Model Piaggio P-180 Airplanes.

Unsafe Condition

Water leakage from the lavatory water duct system could collect in the fuselage, freeze in cold weather conditions, and cause the rudder control system to jam.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Accomplish a leakage check of all lavatory water tube/hose connections within 3 calendar months after the effective date. If leakage is found, correct the installation prior to further flight in accordance with Piaggio Service Bulletin SB-80-0096.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within the next 3 calendar months after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Model Piaggio P-180 airplanes, serial numbers 1002, 1004, 1006 through 1017, 1019, and 1021 through 1030, certificated in any category.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗