AD 98-07-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | 328 Support Services GmbH | 328-100 | Airworthiness Directives; DORNIER Model 328-100 Series Airplanes |
Unsafe Condition
Chafing of engine control cables could cause the cables to break and result in loss of engine control and consequent reduced controllability of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a one-time inspection for chafing or discrepancies of engine control cables in the areas of the cable fairleads on the nose rib firewall and fuselage. Replace damaged cables with new or serviceable cables if found. Modify the cable fairleads on the nose rib firewall or the mounting brackets of the control cable pulleys in the pulley box, depending on the applicable service bulletin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 90 days after the effective date of this AD, or prior to further flight following the inspection.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 series airplanes listed in Dornier Service Bulletins SB-328-76-152 and SB-328-76-168.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗