AD 98-06-16
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | 328 Support Services GmbH | 328-100 | Airworthiness Directives; DORNIER Model 328-100 Series Airplanes |
Unsafe Condition
Failure of an engine or direct current (DC) generator during takeoff and landing, coupled with an open DC tie, could cause the avionics to fail, specifically the No. 2 primary flight and multiple function displays, or the autopilot/yaw damper servos.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the wiring supplying power from non-essential bus 2 to the bus 2 avionics circuit, and from non-essential bus 1 to the bus 1 avionics circuit, in accordance with Dornier Service Bulletin SB-328-24-062, Revision 1, dated June 27, 1995.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 6 months after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 series airplanes having serial numbers 3005 through 3024 inclusive
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain