AD 98-01-11

final rule
Data completeness: 70%

Airworthiness Directives; DORNIER Model 328-100 Series Airplanes

AD Number
98-01-11
Status
final_rule
Effective Date
Product Category
aircraft
Docket
97-NM-113-AD
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft 328 Support Services GmbH 328-100 Airworthiness Directives; DORNIER Model 328-100 Series Airplanes

Unsafe Condition

Loose electrical connections in the passenger cabin could increase electrical resistance, leading to overheating at the terminals and potential smoke/fire.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace electrical terminals in the passenger cabin with new terminals per Dornier Service Bulletin SB-328-24-188. Do not install terminals with part numbers 001A903A8010002, 001A903A8020002, or 001A903A8030002.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 100 flight hours after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Dornier Model 328-100 series airplanes, serial numbers 3005 through 3015 inclusive

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.