AD 98-01-11
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | 328 Support Services GmbH | 328-100 | Airworthiness Directives; DORNIER Model 328-100 Series Airplanes |
Unsafe Condition
Loose electrical connections in the passenger cabin could increase electrical resistance, leading to overheating at the terminals and potential smoke/fire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace electrical terminals in the passenger cabin with new terminals per Dornier Service Bulletin SB-328-24-188. Do not install terminals with part numbers 001A903A8010002, 001A903A8020002, or 001A903A8030002.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 100 flight hours after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 series airplanes, serial numbers 3005 through 3015 inclusive
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain