AD 97-23-10
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | 328 Support Services GmbH | 328-100 | Airworthiness Directives; DORNIER Model 328-100 Series Airplanes |
Unsafe Condition
Failure of the cable tension regulator on both the left and right elevators, and consequent reduced controllability of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 6 months after the effective date of this AD, modify the cable tension regulator on both the left and right elevators by installing two lateral plates on the lever arm in accordance with Dornier Service Bulletin SB-328-27-116, dated September 26, 1995. An alternative method of compliance or adjustment of the compliance time may be approved by the Manager, International Branch, ANM-116, FAA.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 6 months after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Model 328-100 series airplanes having serial numbers 3005 through 3045 inclusive; certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain