AD 97-21-04

final rule
Data completeness: 70%

Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines

AD Number
97-21-04
Status
final_rule
Effective Date
Product Category
aircraft
Docket
96-NM-64-AD
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Airbus SAS A300 B4-620 Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines
aircraft Airbus SAS A300 B4-622R Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines
aircraft Airbus SAS A310-221 Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines
aircraft Airbus SAS A310-222 Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines
aircraft Airbus SAS A310-322 Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines
aircraft Airbus SAS A310-324 Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines
aircraft Airbus SAS A310-325 Airworthiness Directives; Airbus Model A310 and A300-600 Series Airplanes Equipped with Pratt & Whitney Turbofan Engines

Unsafe Condition

Clogging of the hydraulic pump drain system could cause failure of the seal of the hydraulic pump shaft and subsequent contamination of the engine accessory gearbox oil, which could result in an in-flight engine shutdown.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a flow check of the hydraulic pump drain system within 30 days after the effective date and correct discrepancies before further flight. Repeat flow checks every 500 flight hours until the seal replacement is done. Replace the existing seal of the green hydraulic system gearbox within 12 months using specified service bulletins.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 30 days after the effective date (for initial flow check) and within 12 months after the effective date (for seal replacement). Repeat flow checks at intervals not exceeding 500 flight hours.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Airbus Model A300B4-620, -622, -622R, A300C4-620, A310-221, -222, -322, -324, -325 series airplanes equipped with Pratt & Whitney turbofan engines where Modification 10399 or 10400 has not been accomplished.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain