AD 97-02-03

final rule
Data completeness: 70%

Airworthiness Directives; Fokker Model F28 Mark 0100 Series Airplanes

AD Number
97-02-03
Status
final_rule
Effective Date
Product Category
aircraft
Docket
96-NM-70-AD
FR Citation
This information is not available.

Unsafe Condition

Incorrect routing and incorrect tension of the flight control lock cables and elevator control cables could result in inadvertent disconnection of those cables, and consequent reduced controllability of the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a one-time visual inspection to verify correct routing and tension of the flight control lock cables and elevator control cables per Fokker Service Bulletin SBF100-27-064. If routing or tension is incorrect, reroute and/or adjust tension prior to further flight as specified in the service bulletin.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 60 days after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Fokker Model F28 Mark 0100 series airplanes with serial numbers 11323 through 11326 inclusive, 11423, 11429, 11431, 11441, 11444, and 11445.

AI-generated summary from the source AD text. Verify against the official source before acting.