AD 96-23-13
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier Inc. | CL-215-1A10 | Airworthiness Directives; Canadair Model CL-215-1A10 Series Airplanes |
Unsafe Condition
Extra unconnected bare copper wire inside DC generators (part number 2CM70D-( )) could cause a short circuit and present a fire hazard if a combustible fuel-air mixture is present.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a one-time visual inspection of the three DC generators (ENG1, ENG2, and GPU2) to ensure the extra unconnected bare copper wire is properly insulated and stowed. If not, rework it before further flight as per Service Bulletin 215-414.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 hours time-in-service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Canadair Model CL-215-1A10 series airplanes with serial numbers 1001 to 1107 inclusive, and 1110 to 1113 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.