AD 96-20-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | BAE Systems (Operations) Limited | HS 748 Series 2A | Airworthiness Directives; Jetstream Model HS 748 Series Airplanes |
| aircraft | BAE Systems (Operations) Limited | HS 748 Series 2B | Airworthiness Directives; Jetstream Model HS 748 Series Airplanes |
Unsafe Condition
Jamming of the flight control cable tension regulators and gust lock mechanisms, which could result in inability to achieve full deflection of associated flight control surfaces and reduced controllability.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a one-time inspection of aileron, rudder, and elevator cable tensioners and gust lock levers to ensure proper operation, positioning, and lubrication. Inspect cable pressure seals for correct positioning and contamination, correct any discrepancies, and revise the FAA-approved maintenance program to include these inspections repetitively.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 600 hours time-in-service or 6 months after the effective date of this AD, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
BAE Systems (Operations) Limited Model HS 748 Series 2A and HS 748 Series 2B airplanes, all serial numbers.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.