AD 96-18-20

final rule
Data completeness: 70%

Airworthiness Directives; Piaggio Model P-180 Airplanes

AD Number
96-18-20
Status
final_rule
Effective Date
Product Category
aircraft
Docket
95-NM-256-AD
FR Citation
[Federal Register: September 9, 1996 (Volume 61, Number 175)

Applicability

TypeManufacturerModelDetails
aircraft Piaggio Aero Industries S.p.A. P-180 Airworthiness Directives; Piaggio Model P-180 Airplanes

Unsafe Condition

Cracking and subsequent failure of outflow/safety valves in the pressurization system could result in rapid decompression of the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace the outflow/safety valve in accordance with Allied Signal Aerospace Service Bulletins 103742-21-4059 or 103744-21-4060, dated March 31, 1995, as applicable. Ensure that no person installs non-serviceable valves with specified part and serial numbers.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 18 months after the effective date of this AD (October 15, 1996)

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Piaggio Model P-180 airplanes equipped with Allied Signal outflow/safety valves as specified in Service Bulletins 103742-21-4059 and 103744-21-4060, dated March 31, 1995.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain