AD 96-16-05

final rule
Data completeness: 70%

Airworthiness Directives; Fokker Model F28 Mark 1000, 2000, 3000, and 4000 Series Airplanes, and Model F28 Mark 0100 Series Airplanes

AD Number
96-16-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
95-NM-87-AD
FR Citation
This information is not available.

Unsafe Condition

Collapse of the main landing gear (MLG) under extreme inward side-load conditions (such as touching down at large 'crab' angles) due to a lock toggle-link being pulled out of its over-center position by a bottomed MLG downlock-actuator, as a result of the relative movement of the upper and lower side stay members.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a pre-load adjustment of the MLG downlock-actuator within 8 months after the effective date of this AD using specified service bulletins. Repeat the adjustment at each installation or replacement of the actuator unless an alternative maintenance program is incorporated as described.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within 8 months after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Fokker Model F28 Mark 1000, 2000, 3000, 4000, and 0100 series airplanes equipped with specific Dowty Aerospace main landing gear downlock-actuators (part numbers listed in the AD).

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain