AD 96-13-12
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | 328 Support Services GmbH | 328-100 | Airworthiness Directives; DORNIER Model 328-100 Series Airplanes |
Unsafe Condition
Abnormal functions of the bus power control units and generator control units could result in electrical short circuits in the electrical power distribution systems and a subsequent fire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 3 months after the effective date, remove and replace generator control units 2PC and 12PC with new units having part number 118-000-1, and remove and replace bus power control unit 20PC with a new unit having part number 106-000-3, in accordance with Dornier Service Bulletin SB-328-24-061, Revision 1.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 3 months after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
DORNIER Model 328-100 series airplanes with serial numbers 3005 through 3024 inclusive
AI-generated summary from the source AD text. Verify against the official source before acting.