Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier Inc. | CL-215-1A10 | Airworthiness Directives; Canadair Model CL-215-1A10 Series Airplanes |
Unsafe Condition
Loose or missing hardware on a terminal from an inverter power relay shorted out a voltage regulator in the main distribution center, causing total loss of electrical power during flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the main distribution center and all electrical components for loose or missing hardware, verify and adjust torque values, restore or apply humiseal coatings, safety-wire electrical connectors, and remove loose hardware or foreign objects as per Canadair Alert Service Bulletin 215-A439.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 10 flight hours after the effective date of this AD. Discrepancies must be corrected prior to further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Canadair Model CL-215-1A10 series airplanes, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.