Unsafe Condition
Electrical arcing between the flexible fuel drain line and starter motor positive terminal of the auxiliary power unit (APU), which could lead to a fire in the APU.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a visual inspection of the APU flexible fuel drain line and its braiding. If no damage is found, install two additional clamps on the fuel supply line and flexible fuel drain line. If damage is detected, replace the drain line with a new or serviceable one and install the clamps.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 14 days after the effective date of this AD, or prior to further flight if damage is detected.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Model F28 Mark 0100 series airplanes, serial numbers 11244 through 11405 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.