AD 95-19-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | ATR - GIE Avions de Transport R gional | ATR42-300 | Airworthiness Directives; Aerospatiale Model ATR 42-300 and 42-320 Series Airplanes |
| aircraft | ATR - GIE Avions de Transport R gional | ATR42-320 | Airworthiness Directives; Aerospatiale Model ATR 42-300 and 42-320 Series Airplanes |
Unsafe Condition
Chafing of the 1M wire bundle against a smoke detection pipe causing short circuits and potential fire hazard.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the smoke detection system by replacing the smoke detection pipe in the forward cargo compartment at Frame 16 and installing spacers between the electrical wire bundle (route 1M) and the smoke detection pipe from Frame 16 to Frame 21, in accordance with Service Bulletin ATR42-25-0094.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 2,400 flight hours or 12 months after the effective date of this AD, whichever occurs later.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Aerospatiale Model ATR42-300 and -320 series airplanes as listed and described in Service Bulletin ATR42-25-0094, dated June 23, 1995.
AI-generated summary from the source AD text. Verify against the official source before acting.