AD 95-17-10
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | British Aerospace Regional Aircraft | Jetstream 3201 | Airworthiness Directives; Jetstream Aircraft Limited Models 3101 and 3201 Airplanes |
| aircraft | British Aerospace Regional Aircraft | Jetstream Series 3101 | Airworthiness Directives; Jetstream Aircraft Limited Models 3101 and 3201 Airplanes |
Unsafe Condition
Failure of a diode in the central annunciator panel test button circuit could result in inadvertent engine shutdown while in flight if the central annunciator panel test button is pressed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the central annunciator panel test button circuit by removing diodes from the engine stop circuit and configuring a minor wiring change in accordance with Jetstream Alert Service Bulletin 80-A-JA 911045, Revision 1. Terminals may be linked using 22 AWA cable and terminal tags as specified in the service bulletin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 200 hours time-in-service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Jetstream Aircraft Limited Models 3101 (all serial numbers) and 3201 (serial numbers 790 through 950)
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.