AD 94-13-05

final rule
Data completeness: 70%

Airworthiness Directives; Fokker Model F28 Mark 0100 Series Airplanes

AD Number
94-13-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
94-NM-47-AD
FR Citation
This information is not available.

Unsafe Condition

Electrical wires with a positive voltage were connected to an electrical connector also wired to the liftdumper system, which could negatively affect the liftdumper system and result in reduced protection against uncommanded deployment of the liftdumper.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Modify the electrical connections in the number 2 relay panel in accordance with Fokker Service Bulletin SBF100-21-045 or SBF100-21-056 within 30 days after the effective date. Ensure that any modification under SBF100-21-026 is accompanied by the required electrical connection modification.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 30 days after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Fokker Model F28 Mark 0100 series airplanes with serial numbers 11244 through 11275 inclusive, 11277, and 11279 that have been modified in accordance with Fokker Service Bulletin SBF100-21-026.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.