AD 94-08-11

final rule
Data completeness: 70%

Airworthiness Directives; Jetstream Aircraft Limited Model ATP Airplanes

AD Number
94-08-11
Status
final_rule
Effective Date
Product Category
aircraft
Docket
93-NM-166-AD
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft BAE Systems (Operations) Limited ATP Airworthiness Directives; Jetstream Aircraft Limited Model ATP Airplanes

Unsafe Condition

Localized overheating of the electric power circuit for the air conditioning recirculation fan in the environmental control system (ECS) due to failures of certain Texas Instrument circuit breakers 1HG3 and 2HG3 (P/N 6TC4-10).

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace Texas Instrument circuit breakers 1HG3 and 2HG3 (P/N 6TC4-10) with Genelco circuit breakers (P/N 4330-014-10) on left- and right-hand AC generator panel assemblies at zones 131-05-00 and 132-05-00, following Jetstream Service Bulletin ATP-21-24-10306A.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 600 hours time-in-service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Jetstream Aircraft Limited Model ATP airplanes, serial numbers 2002 through 2065 inclusive, certificated in any category.