AD 94-07-07
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | The Boeing Company | MD-11 | Airworthiness Directives; MCDONNELL DOUGLAS MD-11 and MD-11F Airplanes |
| aircraft | The Boeing Company | MD-11F | Airworthiness Directives; MCDONNELL DOUGLAS MD-11 and MD-11F Airplanes |
Unsafe Condition
Failure of the number 2 DC bus electrical relay and subsequent loss of the number 2 electrical power source could cause an all-engine flameout event due to fuel starvation during or shortly after a fuel dumping operation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the fuel crossfeed low level dump system shutoff in accordance with McDonnell Douglas MD-11 Service Bulletin 28-48, dated September 30, 1993. This modification terminates the AFM revisions required by AD 92-22-06.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 24 months after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
McDonnell Douglas Model MD-11 and MD-11F airplanes with fuselage numbers 447 through 544 inclusive
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain