AD 93-22-01

final rule
Data completeness: 70%

Airworthiness Directives; FOKKER Model F28 Mk 0100 Series Airplanes

AD Number
93-22-01
Status
final_rule
Effective Date
Product Category
aircraft
Docket
93-NM-84-AD
FR Citation
This information is not available.

Unsafe Condition

Inadvertent positive voltage on the wiring of the liftdumper system.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the liftdumper system wiring shield ground connections to ensure shields are connected to ground within 8 months after December 16, 1993. If any shield is not grounded, connect it to ground before further flight in accordance with Fokker Service Bulletin SBF100-27-043.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 8 months after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

FOKKER Model F28 Mk 0100 series airplanes, serial numbers 11244 through 11392 inclusive

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.