AD 93-14-18

final rule

GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines

AD Number
93-14-18
Status
final_rule
Effective Date
Product Category
engine
Docket
92-ANE-10
FR Citation
This information is not available.
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

Applicability

TypeManufacturerModelDetails
engine General Electric Company CF6-45A GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-45A2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50A GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50C GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50C1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50C2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50C2B GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50C2D GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50CA GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50E GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50E1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50E2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-50E2B GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-6D GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-6D1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-6D1A GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-6K GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-6K2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80A GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80A1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80A2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80A3 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2A1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2A2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2A3 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2A5 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2A5F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2A8 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B1F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B1F1 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B1F2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B2 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B2F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B3F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B4 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B4F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B5F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B6 GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B6F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B6FA GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2B7F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
engine General Electric Company CF6-80C2D1F GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines

Unsafe Condition

Failure of the high pressure turbine (HPT) thermal shields could result in an uncontained engine failure.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform an impression and optical comparator inspection or ultrasonic inspection of the HPT thermal shield at the next HPT shop visit or by December 12, 1995, whichever occurs first. Replace HPT thermal shields that do not meet service criteria with a serviceable part prior to further flight.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

by December 12, 1995, or at the next HPT shop visit, whichever occurs first

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

General Electric Company CF6-6/-45/-50/-80A/-80C2 series turbofan engines installed on Airbus A300/A310, Boeing 747/767, and McDonnell Douglas DC-10/MD-11 aircraft, as listed in referenced service bulletins.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

High pressure turbine (HPT) thermal shields

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_93-14-18.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
93-14-18
Document Type:
AD Final Rules
Docket Number:
92-ANE-10
Subject Heading:
GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
Subject:
High pressure turbine (HPT) thermal shields
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
10/04/1993
Make:
General Electric Company
Model:
CF6-45A | CF6-45A2 | CF6-50A | CF6-50C | CF6-50C1 | CF6-50C2 | CF6-50C2B | CF6-50C2D | CF6-50CA | CF...Show more
Product Type:
Engine
Product Subtype:
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 93-14-18
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   92-ANE-10

AMENDMENT:   39-8643

AD NUMBER:   93-14-18

SUBJECT HEADING:   GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines

ACTION:  

SUMMARY:  

DATES:   Effective October 4, 1993.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   93-14-18 GENERAL ELECTRIC COMPANY: Amendment 39-8643. Docket 92-ANE-10.

Applicability: General Electric Company (GE) CF6-6/-45/-50/-80A/-80C2 series turbofan engines that contain high pressure turbine (HPT) thermal shields as listed in the applicable service bulletins that are referenced in this AD, installed on but not limited to Airbus A300 and A310 series, Boeing 747 and 767 series, and McDonnell Douglas DC-10 and MD-11 series aircraft.

Compliance: Required as indicated, unless accomplished previously.

To prevent an uncontained engine failure, accomplish the following:

(a) Perform either an impression and optical comparitor inspection or an ultrasonic inspection of the HPT thermal shield at the next HPT shop visit, or by December 12, 1995, whichever occurs first, as follows:

(1) For GE CF6-6 engines, in accordance with GE CF6-6 Service Bulletin (SB) No. 72-983, Revision 1, dated October 10, 1991.

(2) For CF6-45/-50 engines, in accordance with GE CF6-50 SB No. 72-1021, Revision 1, dated October 10, 1991.

(3) For CF6-80A engines, in accordance with GE CF6-80A SB No. 72-596, Revision 1, dated October 10, 1991.

(4) For CF6-80C2 engines, in accordance with GE CF6-80C2 SB No. 72-565, Revision 1, dated October 10, 1991.

(b) Remove from service prior to further flight, and replace with a serviceable part, HPT thermal shields that do not meet the service criteria contained in the applicable service bulletins as specified in paragraph (a) of this AD.

(c) For the purpose of this AD, a shop visit is defined as the removal of the HPT module from the engine for any reason.

(d) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Engine Certification Office. The request should be forwarded through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Engine Certification Office.

NOTE: Information concerning the existence of approved alternative methods of compliance with this airworthiness directive, if any, may be obtained from the Engine Certification Office.

(e) Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished.

(f) The inspections shall be done in accordance with the following service bulletins:

Document No.	Pages	Revision	Date
GE CF6-6 SB	1-3	1	October 10, 1991
No. 72-983	4-30	Original	September 19, 1991
Total Pages: 30			
GE CF6-50 SB	1-3	1	October 10, 1991
No. 72-1021	4-30	Original	September 19, 1991
Total Pages: 30			
GE CF6-80A SB	1-3	1	October 10, 1991
No. 72-596	4-31	Original	September 19, 1991
Total Pages: 31			

This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from General Electric Aircraft Engines, CF6 Distribution Clerk, Room 132, 111 Merchant Street, Cincinnati, OH 45246. Copies may be inspected at the FAA, New England Region, Office of the Assistant Chief Counsel, 12 New England Executive Park, Burlington, MA; or at the Office of the Federal Register, 800 North Capitol Street NW., suite 700, Washington, DC.

(g) This amendment becomes effective on October 4, 1993.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_93-14-18.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
93-14-18
Document Type:
AD Final Rules
Docket Number:
92-ANE-10
Subject Heading:
GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines
Subject:
High pressure turbine (HPT) thermal shields
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
10/04/1993
Make:
General Electric Company
Model:
CF6-45A | CF6-45A2 | CF6-50A | CF6-50C | CF6-50C1 | CF6-50C2 | CF6-50C2B | CF6-50C2D | CF6-50CA | CF...Show more
Product Type:
Engine
Product Subtype:
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 93-14-18
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   92-ANE-10

AMENDMENT:   39-8643

AD NUMBER:   93-14-18

SUBJECT HEADING:   GENERAL ELECTRIC COMPANY Models (GE) CF6-6/-45/-50/-80A/-80C2 Series Engines

ACTION:  

SUMMARY:  

DATES:   Effective October 4, 1993.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   93-14-18 GENERAL ELECTRIC COMPANY: Amendment 39-8643. Docket 92-ANE-10.

Applicability: General Electric Company (GE) CF6-6/-45/-50/-80A/-80C2 series turbofan engines that contain high pressure turbine (HPT) thermal shields as listed in the applicable service bulletins that are referenced in this AD, installed on but not limited to Airbus A300 and A310 series, Boeing 747 and 767 series, and McDonnell Douglas DC-10 and MD-11 series aircraft.

Compliance: Required as indicated, unless accomplished previously.

To prevent an uncontained engine failure, accomplish the following:

(a) Perform either an impression and optical comparitor inspection or an ultrasonic inspection of the HPT thermal shield at the next HPT shop visit, or by December 12, 1995, whichever occurs first, as follows:

(1) For GE CF6-6 engines, in accordance with GE CF6-6 Service Bulletin (SB) No. 72-983, Revision 1, dated October 10, 1991.

(2) For CF6-45/-50 engines, in accordance with GE CF6-50 SB No. 72-1021, Revision 1, dated October 10, 1991.

(3) For CF6-80A engines, in accordance with GE CF6-80A SB No. 72-596, Revision 1, dated October 10, 1991.

(4) For CF6-80C2 engines, in accordance with GE CF6-80C2 SB No. 72-565, Revision 1, dated October 10, 1991.

(b) Remove from service prior to further flight, and replace with a serviceable part, HPT thermal shields that do not meet the service criteria contained in the applicable service bulletins as specified in paragraph (a) of this AD.

(c) For the purpose of this AD, a shop visit is defined as the removal of the HPT module from the engine for any reason.

(d) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Engine Certification Office. The request should be forwarded through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Engine Certification Office.

NOTE: Information concerning the existence of approved alternative methods of compliance with this airworthiness directive, if any, may be obtained from the Engine Certification Office.

(e) Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished.

(f) The inspections shall be done in accordance with the following service bulletins:

Document No.	Pages	Revision	Date
GE CF6-6 SB	1-3	1	October 10, 1991
No. 72-983	4-30	Original	September 19, 1991
Total Pages: 30			
GE CF6-50 SB	1-3	1	October 10, 1991
No. 72-1021	4-30	Original	September 19, 1991
Total Pages: 30			
GE CF6-80A SB	1-3	1	October 10, 1991
No. 72-596	4-31	Original	September 19, 1991
Total Pages: 31			

This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from General Electric Aircraft Engines, CF6 Distribution Clerk, Room 132, 111 Merchant Street, Cincinnati, OH 45246. Copies may be inspected at the FAA, New England Region, Office of the Assistant Chief Counsel, 12 New England Executive Park, Burlington, MA; or at the Office of the Federal Register, 800 North Capitol Street NW., suite 700, Washington, DC.

(g) This amendment becomes effective on October 4, 1993.

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.