AD 92-18-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Gulfstream Aerospace LP | 1125 Westwind Astra | Airworthiness Directives; ISRAEL AIRCRAFT INDUSTRIES, LTD. Model 1125 Astra Series Airplanes |
Unsafe Condition
Chafing and damage to the oxygen tubing could lead to increased potential for fire ignited from arcing or heated components.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect all oxygen tubing for security, chafing, and general condition within 200 hours time-in-service or 6 months after the effective date, whichever occurs first. If discrepancies are found, protect the oxygen tubing prior to further flight. Actions must follow Astra SB 1125-35-071.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 200 hours time-in-service or 6 months after the effective date of this AD, whichever occurs first
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Model 1125 Astra series airplanes, all serial numbers prior to 059; certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain