AD 86-08-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Short Brothers PLC | SD3-30 | Airworthiness Directives; SHORT BROTHERS, LTD. Model SD3-30 and SD3-60 Series Airplanes |
| aircraft | Short Brothers PLC | SD3-60 | Airworthiness Directives; SHORT BROTHERS, LTD. Model SD3-30 and SD3-60 Series Airplanes |
Unsafe Condition
Leaks in the collector tank housing could lead to fuel leakage, which may result in fire or loss of engine power.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within seven days after the effective date, inspect the collector tank housing per applicable service bulletins. If leaks are found, replace shrouds and seals before further flight. Repeat inspection every 120 hours time in service if no leaks are found.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within seven days after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Short Brothers PLC Model SD3-30 (serial numbers SH3002 through SH3099, SH3102, SH3105) and SD3-60 (serial numbers SH3601 through SH3661, SH3663 through SH3665) airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain